Pipe Material |
Steel, cast iron, plastic, cement, etc which are not amenable to welding process |
Fluids measured |
Water, sewage and other homogeneous fluids in full pipe flow |
Accuracy, % |
¡À2.0 |
Pipe Size Adaptable, mm |
DN300~DN3000 |
Working Environment |
Temperature: -10¡æ~+45¡æ Humidity: ¡Ü85% (RH) For use under otherwise
specific conditions, please specify on ordering |
Output Selectable |
Analog |
4¡«20mA¡£ |
| Digital |
RS485 GSM radio meter data transmission |
Keyboard |
1X2 magnetic induction keys |
Display |
LCD 8-digit + prompting character Word height: 8.5mm |
Data Displayed |
Instantaneous flowrate, m3/h Cumulative flowrate, m3 Cumulative effective
running time, h Date:(Y/M/D) Clock:(h/m/s) |
Data Storage |
Storage of cumulative flowrate and effective running time in EEPROM. |
Power Supply |
Battery (The meter is capacity of working continuously for over 6 years with a battery cell) |
Protection Class |
Conversion unit£ºIP68 |
Display: Non-integral type: IP65,Panel-mounted type: IP51 |
Power Consumption |
¡´0.8mW |
The standard length of the cable connecting the conversion unit and the transducer of a non-integral version: 6m (For a cable length other than this, please specify on ordering). |
Material |
1Cr18Ni9Ti (Stainless steel) |
Pressure-bearing Capacity |
¡Ü2MPa |
Temperature of Fluids Adaptable |
Normal temperature version: 4~50¡æ High-temperature version: 4~150¡æ |
Weight of Paired Transducers, kg |
3.5 (including that of the 1-m cable) |
Cable¡¯s Ambient Temperature, ¡æ |
-40¡æ¡«+65¡æ |
Protection Class |
IP68 |