Product Retrieval
 
   Product Description
   Technical Specifications
   Model Selection
 SCL-73xLL Series Insertion-Type Dual-transducer Ultrasonic Flowmeter
 Technical Parameters
Transducer Adaptability & Mounting Instruction
  Technical Parameters:
 

Pipe Material

 Steel, cast iron, plastic, cement, etc which are not amenable to welding process

Fluids measured

 Water, sewage and other homogeneous fluids in full pipe flow

Accuracy, %

 ¡À2.0

Pipe Size Adaptable, mm

 DN300~DN3000

Working Environment

 Temperature: -10¡æ~+45¡æ Humidity: ¡Ü85% (RH) For use under otherwise
  specific conditions, please specify on ordering
Output Selectable
Analog

 4¡«20mA¡£

Digital

 RS485 GSM radio meter data transmission

Keyboard

 1X2 magnetic induction keys

Display

 LCD 8-digit + prompting character Word height: 8.5mm

Data Displayed
 Instantaneous flowrate, m3/h Cumulative flowrate, m3  Cumulative effective
  running time, h  Date:(Y/M/D) Clock:(h/m/s)
Data Storage
 Storage of cumulative flowrate and effective running time in EEPROM.
Power Supply
 Battery (The meter is capacity of working continuously for over 6 years with a  battery cell)
Protection Class

 Conversion unit£ºIP68

 Display: Non-integral type: IP65,Panel-mounted type: IP51

Power Consumption

 ¡´0.8mW

The standard length of the cable connecting the conversion unit and the transducer of a non-integral version: 6m (For a cable length other than this, please specify on ordering).

Material

 1Cr18Ni9Ti (Stainless steel)

Pressure-bearing Capacity

 ¡Ü2MPa

Temperature of Fluids Adaptable

 Normal temperature version: 4~50¡æ High-temperature version: 4~150¡æ

Weight of Paired Transducers, kg
 3.5 (including that of the 1-m cable)
Cable¡¯s Ambient Temperature, ¡æ

 -40¡æ¡«+65¡æ

Protection Class

 IP68


 

Tangshan Huizhong Instrumentation Co., Ltd. Tangshan Huizhong Wylton Instrumentation Co., Ltd.

Add: Qinghua Road, New and Hi-Tech Development Zone, Tangshan, Hebei Province, China Postcode: 063020